Sustained Improvement in Tracheal Intubation Safety Across a 15-Center Quality-Improvement Collaborative: An Interventional Study From the National Emergency Airway Registry for Children Investigators.
Critical Care Medicine 2021 Februrary 2
OBJECTIVES: To evaluate the effect of a tracheal intubation safety bundle on adverse tracheal intubation-associated events across 15 PICUs.
DESIGN: Multicenter time-series study.
SETTING: PICUs in the United States.
PATIENTS: All patients received tracheal intubations in ICUs.
INTERVENTIONS: We implemented a tracheal intubation safety bundle as a quality-improvement intervention that includes: 1) quarterly site benchmark performance report and 2) airway safety checklists (preprocedure risk factor, approach, and role planning, preprocedure bedside "time-out," and immediate postprocedure debriefing). We define each quality-improvement phase as baseline (-24 to -12 mo before checklist implementation), benchmark performance reporting only (-12 to 0 mo before checklist implementation), implementation (checklist implementation start to time achieving > 80% bundle adherence), early bundle adherence (0-12 mo), and sustained (late) bundle adherence (12-24 mo). Bundle adherence was defined a priori as greater than 80% of checklist use for tracheal intubations for 3 consecutive months.
MEASUREMENTS AND MAIN RESULTS: The primary outcome was the adverse tracheal intubation-associated event, and secondary outcomes included severe tracheal intubation-associated events, multiple tracheal intubation attempts, and hypoxemia less than 80%.From January 2013 to December 2015, out of 19 participating PICUs, 15 ICUs (79%) achieved bundle adherence. Among the 15 ICUs, the adverse tracheal intubation-associated event rates were baseline phase: 217/1,241 (17.5%), benchmark reporting only phase: 257/1,750 (14.7%), early 0-12 month complete bundle compliance phase: 247/1,591 (15.5%), and late 12-24 month complete bundle compliance phase: 137/1,002 (13.7%). After adjusting for patient characteristics and clustering by site, the adverse tracheal intubation-associated event rate significantly decreased compared with baseline: benchmark: odds ratio, 0.83 (0.72-0.97; p = 0.016); early bundle: odds ratio, 0.80 (0.63-1.02; p = 0.074); and late bundle odds ratio, 0.63 (0.47-0.83; p = 0.001).
CONCLUSIONS: Effective implementation of a quality-improvement bundle was associated with a decrease in the adverse tracheal intubation-associated event that was sustained for 24 months.
DESIGN: Multicenter time-series study.
SETTING: PICUs in the United States.
PATIENTS: All patients received tracheal intubations in ICUs.
INTERVENTIONS: We implemented a tracheal intubation safety bundle as a quality-improvement intervention that includes: 1) quarterly site benchmark performance report and 2) airway safety checklists (preprocedure risk factor, approach, and role planning, preprocedure bedside "time-out," and immediate postprocedure debriefing). We define each quality-improvement phase as baseline (-24 to -12 mo before checklist implementation), benchmark performance reporting only (-12 to 0 mo before checklist implementation), implementation (checklist implementation start to time achieving > 80% bundle adherence), early bundle adherence (0-12 mo), and sustained (late) bundle adherence (12-24 mo). Bundle adherence was defined a priori as greater than 80% of checklist use for tracheal intubations for 3 consecutive months.
MEASUREMENTS AND MAIN RESULTS: The primary outcome was the adverse tracheal intubation-associated event, and secondary outcomes included severe tracheal intubation-associated events, multiple tracheal intubation attempts, and hypoxemia less than 80%.From January 2013 to December 2015, out of 19 participating PICUs, 15 ICUs (79%) achieved bundle adherence. Among the 15 ICUs, the adverse tracheal intubation-associated event rates were baseline phase: 217/1,241 (17.5%), benchmark reporting only phase: 257/1,750 (14.7%), early 0-12 month complete bundle compliance phase: 247/1,591 (15.5%), and late 12-24 month complete bundle compliance phase: 137/1,002 (13.7%). After adjusting for patient characteristics and clustering by site, the adverse tracheal intubation-associated event rate significantly decreased compared with baseline: benchmark: odds ratio, 0.83 (0.72-0.97; p = 0.016); early bundle: odds ratio, 0.80 (0.63-1.02; p = 0.074); and late bundle odds ratio, 0.63 (0.47-0.83; p = 0.001).
CONCLUSIONS: Effective implementation of a quality-improvement bundle was associated with a decrease in the adverse tracheal intubation-associated event that was sustained for 24 months.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app