We have located links that may give you full text access.
JOURNAL ARTICLE
REVIEW
Emergency Department Evaluation After Conducted Energy Weapon Use: Review of the Literature for the Clinician.
Journal of Emergency Medicine 2019 November
BACKGROUND: Conductive energy weapons (CEWs) are used daily by law enforcement, and patients are often brought to emergency departments (EDs) for medical clearance.
OBJECTIVE: Our aim was to review the medical literature on the topic of CEWs and to offer evidence-based recommendations to emergency physicians for evaluation and treatment of patients who have received a CEW exposure.
METHODS: A MEDLINE literature search from 1988 to 2018 was performed and limited to human studies published from January 1, 1988 to November 1, 2018 written in English with the following keywords: TASER, conductive energy device(s), electronic weapon(s), conductive energy weapon(s), non-lethal weapon(s), conducted energy device(s), conducted energy weapon(s), conductive electronic device(s), and electronic control device(s). Studies identified then underwent a structured review from which results could be evaluated.
RESULTS: Two hundred and sixty-three articles on CEWs were screened and 37 appropriate articles were rigorously reviewed. Evaluation and treatment recommendations are presented. These studies did not report any evidence of dangerous laboratory abnormalities, physiologic changes, or immediate or delayed cardiac ischemia or dysrhythmias after exposure to CEW electrical discharges of up to 15 s.
CONCLUSIONS: The current medical literature does not support routine performance of laboratory studies, electrocardiography, or prolonged ED observation or hospitalization for ongoing cardiac monitoring after CEW exposure in an otherwise asymptomatic awake and alert patient.
OBJECTIVE: Our aim was to review the medical literature on the topic of CEWs and to offer evidence-based recommendations to emergency physicians for evaluation and treatment of patients who have received a CEW exposure.
METHODS: A MEDLINE literature search from 1988 to 2018 was performed and limited to human studies published from January 1, 1988 to November 1, 2018 written in English with the following keywords: TASER, conductive energy device(s), electronic weapon(s), conductive energy weapon(s), non-lethal weapon(s), conducted energy device(s), conducted energy weapon(s), conductive electronic device(s), and electronic control device(s). Studies identified then underwent a structured review from which results could be evaluated.
RESULTS: Two hundred and sixty-three articles on CEWs were screened and 37 appropriate articles were rigorously reviewed. Evaluation and treatment recommendations are presented. These studies did not report any evidence of dangerous laboratory abnormalities, physiologic changes, or immediate or delayed cardiac ischemia or dysrhythmias after exposure to CEW electrical discharges of up to 15 s.
CONCLUSIONS: The current medical literature does not support routine performance of laboratory studies, electrocardiography, or prolonged ED observation or hospitalization for ongoing cardiac monitoring after CEW exposure in an otherwise asymptomatic awake and alert patient.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app