We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Addition of Nasal Cannula Can Either Impair or Enhance Preoxygenation With a Bag Valve Mask: A Randomized Crossover Design Study Comparing Oxygen Flow Rates.
Anesthesia and Analgesia 2018 April
BACKGROUND: A critical safety component of emergency anesthesia is the avoidance of hypoxemia during the apneic phase of a rapid sequence intubation. Preoxygenation with a bag valve mask (BVM) or anesthetic circuit may be improved with supplemental oxygen by nasal cannula (NC) if there is a mask leak. In addition, NC is recommended for apneic oxygenation after induction and may be placed before preoxygenation. However, the optimum NC flow rate for preoxygenation or whether the presence of NC alone creates a mask leak remains unclear.
METHODS: We performed a randomized crossover study on healthy volunteers comparing BVM alone and BVM with NC flow rates of 0 (NC-0), 5 (NC-5), 10 (NC-10), and 15 (NC-15) liters per minute (lpm). Our primary outcome was end-tidal oxygen (ETO2) after 3-minute preoxygenation.
RESULTS: There was no difference in ETO2 between NC-15, NC-10, or BVM-only at 3 minutes. NC-0 and NC-5 recorded significantly lower ETO2 at all times compared with NC-15, NC-10, or BVM-only (least difference NC-5, -7% [95% confidence interval {CI}, -4% to -10%), NC-0, 16% [95% CI, 13%-19%]). There was a difference in ETO2 between NC-15 and BVM-only at 1 minute (7%; 95% CI, 5%-9%), but not at 2 or 3 minutes. There was no difference in ETO2 between NC-10 and NC-15.
CONCLUSIONS: Our study found that NC at 0 and 5 lpm with a BVM is deleterious to preoxygenation and should be avoided. In addition, a lack of difference between NC-10 and BVM-only demonstrates that NC at flows of at least 10 lpm should not impair the preoxygenation process. While NC-15 may offer a benefit by reaching maximal ETO2 at 1 minute, this would need to be balanced against patient comfort.
METHODS: We performed a randomized crossover study on healthy volunteers comparing BVM alone and BVM with NC flow rates of 0 (NC-0), 5 (NC-5), 10 (NC-10), and 15 (NC-15) liters per minute (lpm). Our primary outcome was end-tidal oxygen (ETO2) after 3-minute preoxygenation.
RESULTS: There was no difference in ETO2 between NC-15, NC-10, or BVM-only at 3 minutes. NC-0 and NC-5 recorded significantly lower ETO2 at all times compared with NC-15, NC-10, or BVM-only (least difference NC-5, -7% [95% confidence interval {CI}, -4% to -10%), NC-0, 16% [95% CI, 13%-19%]). There was a difference in ETO2 between NC-15 and BVM-only at 1 minute (7%; 95% CI, 5%-9%), but not at 2 or 3 minutes. There was no difference in ETO2 between NC-10 and NC-15.
CONCLUSIONS: Our study found that NC at 0 and 5 lpm with a BVM is deleterious to preoxygenation and should be avoided. In addition, a lack of difference between NC-10 and BVM-only demonstrates that NC at flows of at least 10 lpm should not impair the preoxygenation process. While NC-15 may offer a benefit by reaching maximal ETO2 at 1 minute, this would need to be balanced against patient comfort.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app