Alteplase for the treatment of central venous catheter occlusion in children: results of a prospective, open-label, single-arm study (The Cathflo Activase Pediatric Study).

PURPOSE: Alteplase is approved for use in the restoration of function to occluded central venous access devices (CVADs); however, there are few prospective studies in children. This study was undertaken to evaluate the safety and efficacy of alteplase in the treatment of CVAD occlusions in a pediatric population.

MATERIALS AND METHODS: A prospective, multicenter, open-label, single-arm study evaluating a maximum of two doses (< or =2 mg per dose) of alteplase was performed in pediatric patients. Inclusion criteria included patient age less than 17 years with an occluded CVAD (single-, double-, and triple-lumen catheter or implanted port). Patients with hemodialysis catheters, those with known mechanical occlusion, or those considered at high risk for bleeding or embolization were excluded. Assessment of function was made 30 and 120 minutes (if required) after each dose. The primary objective of the study was to evaluate the safety of alteplase as measured by the incidence of intracranial hemorrhage (ICH); secondary objectives included the evaluation of specific targeted serious adverse events and efficacy of alteplase in the restoration of catheter function.

RESULTS: A total of 310 patients (174 male patients, 136 female patients; mean age, 7.2 years; range, 0.04-18.3 y) were treated; 55 of the patients (17.7%) were younger than 2 years of age. No patients experienced ICH (95% CI, 0%-1.2%). Nine serious adverse events were noted in eight patients (2.6% incidence), two of which were attributed by the investigator to study drug administration (one case of sepsis and one case of a ruptured catheter lumen). The cumulative rate of restoration of CVAD function after serial administration of a maximum of two instillations of alteplase, each with a maximum dwell time of 120 minutes, was 82.9% (95% CI, 78.2%-86.9%). Similar rates of catheter function restoration were seen among all catheter types studied; there were no clinically meaningful differences among age or sex subgroups.

CONCLUSION: The administration of alteplase is safe and effective for the restoration of function to CVADs in pediatric patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app